CueServer 2 provides up to eight low-voltage contact-closure inputs. These inputs are designed for connecting switches, buttons, motion detectors, sensors, and most anything that makes an electrical connection between two conductors.

Each contact-closure input can be programmed with any of the available CueScript actions and/or rules to automate any kind of action in CueServer.

Each input floats up to a voltage around 3.3V DC through a weak pull-up resistor. When that input is shorted-to-ground, the CueServer device detects this drop in voltage as a “contact closure”.

Specifications

CS-900 CS-920 CS-940/950
Contact Closure Inputs 8 2 8
Connector 10-Position Pluggable Terminal Block 8-Position Pluggable Terminal Block
(shared with other I/O)
12-Position Pluggable Terminal Block
(shared with RS-232 port)
Pinout 1 = Common (Ground)
2 = Contact 1
3 = Contact 2
4 = Contact 3
5 = Contact 4
6 = Contact 5
7 = Contact 6
8 = Contact 7
9 = Contact 8
10 = Common (Ground)
1 = Contact 1
2 = Contact 2
3 = Common (Ground)
4 = RS-232 Transmit
5 = RS-232 Receive
6 = Aux +5VDC Output
7 = Output 1
8 = Output 2
1 = Common (Ground)
2 = Contact 1
3 = Contact 2
4 = Contact 3
5 = Contact 4
6 = Contact 5
7 = Contact 6
8 = Contact 7
9 = Contact 8
10 = RS-232 Common
11 = RS-232 Transmit
12 = RS-232 Receive